- Date
- 01/20/2017
- W/O
- 619078
- Weather
- Dry
- Operator/Surveyor
- JUAN B
- Sewer ID
- Z00059
- PipeID
- P11509
- Time
- 9:38 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K4264
- Sewer Name
- J JOINT OUTFALL J - UNIT 1G
- City
- PALOS VERDES
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 45
- Purpose
- Routine Assessment
- Project
- WO_619078_TV05169_FEB2017
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- J 0269
- Downstream MH
- J 0270
- Dir. of Survey
- Upstream
- Length Surveyed
- 31.5 ft.
- Total Length
- 31.6 ft.
- Structural Index
- 1
- Structural Quick
- 1500
- Structural Rating
- 5
- O&M Index
- 2
- O&M Quick
- 2500
- O&M Rating
- 10
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 15
Pipe schematic from manhole J 0269 to J 0270 Observation photos (2)

5.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

5.5 ft. - Surface Roughness Increased, from 09 to 03 o'clock, within 8 inches of joint: YES, Start