Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 8, 2016, 04:50 PM
  • 30 0186_30 0185 _08122016_085327.mp4

Date
12/08/2016
W/O
597389
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00860
PipeID
P17887
Time
8:50 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3845
Sewer Name
30 EL PORTO TRUNK
City
MANHATTEN BEACH
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
01
Purpose
Routine Assessment
Project
WO_597389_TV30002_OCT2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
30 0186
Downstream MH
30 0185
Dir. of Survey
Downstream
Length Surveyed
365 ft.
Total Length
365 ft.
Structural Index
3
Structural Quick
4233
Structural Rating
21
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
21
Pipe schematic from manhole 30 0186 to 30 0185
MH: 30 0186MH: 30 0185downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 30 01860 ft. MWM - Water Mark, 15 %of cross sectional area3.1 ft. FM - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES34.1 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"63.1 ft. CM - Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES68.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 68.09"136 ft. FM - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES223 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES291.1 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES306.1 ft. CM - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES360 ft. FC - Fracture Circumferential, from 07 to 11 o'clock, within 8 inches of joint: YES365 ft. AMH - Downstream Manhole, Survey Ends - 30 0185

Observation photos (9)

  • Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

    3.1 ft. - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    34.1 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES

    63.1 ft. - Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 68.09"

    68.1 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 68.09"

  • Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

    136 ft. - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    223 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    291.1 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

    306.1 ft. - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 07 to 11 o'clock, within 8 inches of joint: YES

    360 ft. - Fracture Circumferential, from 07 to 11 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
0MWL
360FC
306.1CM
0AMH30 0186
3.1FM
0MWM
365AMH30 0185
223CL
136FM
63.1CM
34.1TB
68.1TB
291.1CM

Properties (5)

additional_info
SC304595
custom_field_two
2
customer
LACSD
datetime
2016-12-08T08:50:16-08:00
sewer_category
Gravity