Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 6, 2016, 08:03 AM
  • 18 0099_18 0098 _06102016_011228.mp4

Date
10/06/2016
W/O
597011
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00698
PipeID
P13919
Time
1:03 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3731
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_597011_TV18083_OCT2016
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0099
Downstream MH
18 0098
Dir. of Survey
Downstream
Length Surveyed
195.6 ft.
Total Length
195.6 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
2
O&M Quick
2G00
O&M Rating
76
Overall Index
2
Overall Quick
Overall Rating
84
Pipe schematic from manhole 18 0099 to 18 0098
MH: 18 0099MH: 18 0098downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 00990 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MMC - Material Change, Vitrified clay pipe4.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start40.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"62.2 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES63.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"102 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"129.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"161.3 ft. CM - Crack Multiple, from 02 to 10 o'clock, within 8 inches of joint: YES180.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES187.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"193.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish195.6 ft. MGO - General Observation - CONNECTION AT MH 12 ACTIVE195.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0098

Observation photos (5)

  • Material Change, Vitrified clay pipe

    0 ft. - Material Change, Vitrified clay pipe

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    4.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    62.2 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 02 to 10 o'clock, within 8 inches of joint: YES

    161.3 ft. - Crack Multiple, from 02 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    180.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
4.3DAGS
0MWL
40.9TFA
129.4TFA
0AMH18 0099
195.6MGOCONNECTION AT MH 12 ACTIVE
195.6AMH18 0098
180.4CM
187.5TFA
0MWM
193.7DAGS
63.3TFA
62.2CL
161.3CM
0MMC
102TFA

Properties (5)

additional_info
SC303718
custom_field_two
4
customer
LACSD
datetime
2016-10-06T01:03:00-07:00
sewer_category