Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 5, 2016, 11:09 AM
  • 18 0106_18 0105 _05102016_041650.mp4

Date
10/05/2016
W/O
597011
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00698
PipeID
P13926
Time
4:09 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3730
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_597011_TV18083_OCT2016
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0106
Downstream MH
18 0105
Dir. of Survey
Downstream
Length Surveyed
131.6 ft.
Total Length
131.6 ft.
Structural Index
2
Structural Quick
3D2D
Structural Rating
129
O&M Index
2
O&M Quick
2D12
O&M Rating
52
Overall Index
2
Overall Quick
Overall Rating
181
Pipe schematic from manhole 18 0106 to 18 0105
MH: 18 0106MH: 18 0105downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 01060 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0.1 ft. VC - Vermin Cockroach2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES8.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"11.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"48.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"51.4 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"99.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"103.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"125 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish126.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES128.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish128.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish131.6 ft. VC - Vermin Cockroach131.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0105131.6 ft. MGO - General Observation - CONNECTION AT MH 9 ACTIVE

Observation photos (5)

  • Vermin Cockroach

    0.1 ft. - Vermin Cockroach

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    4.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    126.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
0AMH18 0106
103.1TFC
0.1VC
2DAGS
2SAV
2SSS
0MWM
11.3TFA
131.6VC
131.6AMH18 0105
99.9TFC
126.2CL
51.4TBA
131.6MGOCONNECTION AT MH 9 ACTIVE
128.3DAGS
48.3TFC
128.3SSS
125SAV
4.7CL
8.8TFA
0MWL

Properties (5)

additional_info
SC303717
custom_field_two
2
customer
LACSD
datetime
2016-10-05T04:09:00-07:00
sewer_category
Gravity