- Date
- 10/14/2016
- W/O
- 596999
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00659
- PipeID
- P13623
- Time
- 1:49 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3783
- Sewer Name
- 16 LAMANDA PARK TRUNK
- City
- PASADENA
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- WO_596999_TV16077_OCT2016
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 22 in.
- Width
- 22 in.
- Upstream MH
- 16 0572
- Downstream MH
- 16 0571
- Dir. of Survey
- Downstream
- Length Surveyed
- 255.8 ft.
- Total Length
- 255.8 ft.
- Structural Index
- 4
- Structural Quick
- 5132
- Structural Rating
- 11
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 15
Pipe schematic from manhole 16 0572 to 16 0571 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

9.4 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

17.3 ft. - Roots Fine Barrell, from 09 to 03 o'clock, Start

54.3 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start