- Date
- 10/11/2016
- W/O
- 596964
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z01182
- PipeID
- P17631
- Time
- 12:46 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3778
- Sewer Name
- H JOINT OUTFALL H - UNIT 8K RELIEF
- City
- IRWINDALE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 24
- Purpose
- Routine Assessment
- Project
- WO_596964_TV15041_OCT2016
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- H 1205
- Downstream MH
- H 1204
- Dir. of Survey
- Downstream
- Length Surveyed
- 105.8 ft.
- Total Length
- 105.8 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 3
- O&M Quick
- 4121
- O&M Rating
- 6
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 11
Pipe schematic from manhole H 1205 to H 1204 Observation photos (4)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

13.9 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

24 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

103.8 ft. - General Observation - ROACHES IN MH