Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 10, 2016, 09:48 AM
  • H 1210_H 1209 _10102016_024826.mp4

Date
10/10/2016
W/O
596964
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01182
PipeID
P17635
Time
2:48 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3777
Sewer Name
H JOINT OUTFALL H - UNIT 8K RELIEF
City
BALDWIN PARK
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
24
Purpose
Routine Assessment
Project
WO_596964_TV15041_OCT2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
H 1210
Downstream MH
H 1209
Dir. of Survey
Downstream
Length Surveyed
487.6 ft.
Total Length
487.6 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole H 1210 to H 1209
MH: H 1210MH: H 1209downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 12100 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start11.6 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES486.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish486.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish487.6 ft. AMH - Downstream Manhole, Survey Ends - H 1209

Observation photos (3)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

    11.6 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
486.1DAGS
487.6AMHH 1209
0AMHH 1210
486.1SSS
11.6SAV
2SSS
2DAGS
0MWL
0MWM

Properties (6)

additional_info
SC306314
custom_field_two
3
customer
LACSD
datetime
2016-10-10T02:48:12-07:00
sewer_category
Gravity
year_laid