- Date
- 02/02/2017
- W/O
- 622202
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00037
- PipeID
- P10180
- Time
- 10:29 PM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4105
- Sewer Name
- F JOINT OUTFALL F - UNIT 3B
- City
- CERRITOS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 39A
- Purpose
- Routine Assessment
- Project
- WO_622202_DISTRICT02_FEB2017
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 63 in.
- Width
- 63 in.
- Upstream MH
- F 0148
- Downstream MH
- F 0147
- Dir. of Survey
- Downstream
- Length Surveyed
- 735.8 ft.
- Total Length
- 735.8 ft.
- Structural Index
- 3
- Structural Quick
- 3\00
- Structural Rating
- 438
- O&M Index
- 2
- O&M Quick
- 2\12
- O&M Rating
- 294
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 732
Pipe schematic from manhole F 0148 to F 0147 Observation photos (3)

2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

391.5 ft. - General Photograph