- Date
- 02/01/2017
- W/O
- 619078
- Weather
- Dry
- Operator/Surveyor
- R,VARGAS
- Sewer ID
- Z00059
- PipeID
- P11542
- Time
- 11:32 PM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4103
- Sewer Name
- J JOINT OUTFALL J - UNIT 1G
- City
- RANCHO PALOS VERDES
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 41
- Purpose
- Routine Assessment
- Project
- WO_619078_TV05169_FEB2017
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- J 0301
- Downstream MH
- J 0300
- Dir. of Survey
- Downstream
- Length Surveyed
- 300.5 ft.
- Total Length
- 300.6 ft.
- Structural Index
- 3
- Structural Quick
- 3K00
- Structural Rating
- 177
- O&M Index
- 2
- O&M Quick
- 3D2K
- O&M Rating
- 196
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 373
Pipe schematic from manhole J 0301 to J 0300 Observation photos (3)

2.5 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

278.8 ft. - General Photograph