Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 18, 2017, 12:40 AM
  • 01 0453_01 0452_010102_012614.mp4

Date
02/17/2017
W/O
624309
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00208
PipeID
P00935
Time
4:40 PM
Certificate
U-7150-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
4310
Sewer Name
01 HOLMES-WILLOWBROOK TRUNK
City
LOS ANGELES
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
WO_624309_TV01032_MAR2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0453
Downstream MH
01 0452
Dir. of Survey
Downstream
Length Surveyed
296.7 ft.
Total Length
296.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2K00
O&M Rating
118
Overall Index
2
Overall Quick
Overall Rating
118
Pipe schematic from manhole 01 0453 to 01 0452
MH: 01 0453MH: 01 0452downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 04530 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area3.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start3.5 ft. MGO - General Observation - PIPE LINED8.6 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"13.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"39.6 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"47.3 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"57.9 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"78.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"87.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"108 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"110.9 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"123.5 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"126.2 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"161.9 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"212.8 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"233.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"241.2 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"263.5 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"296.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Finish296.7 ft. AMH - Downstream Manhole, Survey Ends - 01 0452296.7 ft. MGO - General Observation - DROP CONNECTION AT 3 O CLOCK

Observations (24)

DistanceCodeObservation
296.7DAGS
57.9TF
110.9TF
3.5DAGS
0AMH01 0453
161.9TF
233.3TF
296.7AMH01 0452
78.3TF
0MWM
212.8TF
0MWL
8.6TF
296.7MGODROP CONNECTION AT 3 O CLOCK
13.7TF
241.2TF
123.5TF
126.2TF
108TF
47.3TF
87.8TF
3.5MGOPIPE LINED
263.5TF
39.6TF

Properties (6)

additional_info
SC318727
custom_field_two
4
customer
LACSD
datetime
2017-02-17T16:40:06-08:00
sewer_category
Gravity
year_laid