Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 9, 2017, 08:20 AM
  • 17 0007_17 0006 _02092017_002113.mp4

Date
02/09/2017
W/O
618954
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00668
PipeID
P13732
Time
12:20 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4236
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
07
Purpose
Routine Assessment
Project
WO_618954_TV17003_FEB2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
17 0007
Downstream MH
17 0006
Dir. of Survey
Downstream
Length Surveyed
280.7 ft.
Total Length
280.7 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
135
O&M Index
2
O&M Quick
4132
O&M Rating
122
Overall Index
2
Overall Quick
Overall Rating
257
Pipe schematic from manhole 17 0007 to 17 0006
MH: 17 0007MH: 17 0006downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 17 00070 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start7 ft. RML - Roots Medium Lateral, from 01 to 04 o'clock, 15 %, within 8 inches of joint: YES7 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"54.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start77 ft. RML - Roots Medium Lateral, from 08 to 12 o'clock, 10 %, within 8 inches of joint: YES77 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"80.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"153.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"205.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"225.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"279.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish279.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish280.7 ft. AMH - Downstream Manhole, Survey Ends - 17 0006280.7 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Roots Medium Lateral, from 01 to 04 o'clock, 15 %, within 8 inches of joint: YES

    7 ft. - Roots Medium Lateral, from 01 to 04 o'clock, 15 %, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    54.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Roots Medium Lateral, from 08 to 12 o'clock, 10 %, within 8 inches of joint: YES

    77 ft. - Roots Medium Lateral, from 08 to 12 o'clock, 10 %, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
2DAGS
54.8CM
225.7TFA
205.8TFA
280.7AMH17 0006
7RML
153.3TFA
0MWM
279.5CM
77RML
0AMH17 0007
280.7MGOACTIVE CONNECTION AT MH 9 O'CLOCK
7TB
279.5DAGS
77TBA
0MWL
80.9TBA
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK

Properties (5)

additional_info
SC306738
custom_field_two
4
customer
LACSD
datetime
2017-02-09T00:20:49-08:00
sewer_category
Gravity