Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 21, 2016, 06:34 AM
  • E 0055_E 0054_20161021_010803.mp4

Date
10/20/2016
W/O
597393
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00028
PipeID
P11283
Time
11:34 PM
Certificate
U209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3860
Sewer Name
E JOINT OUTFALL E - UNIT 2
City
LYNWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
16
Purpose
Routine Assessment
Project
WO_597393_TV01124_OCT2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
54 in.
Upstream MH
E 0055
Downstream MH
E 0054
Dir. of Survey
Downstream
Length Surveyed
600 ft.
Total Length
600 ft.
Structural Index
3
Structural Quick
3W00
Structural Rating
354
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
354
Pipe schematic from manhole E 0055 to E 0054
MH: E 0055MH: E 0054downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - E 00556 ft. MGO - General Observation - Magnesium hydroxide coating start6 ft. MGO - General Observation - COCKROACHES6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start581.2 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"595.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish596.6 ft. MGO - General Observation - Magnesium hydroxide coating finish600 ft. AMH - Downstream Manhole, Survey Ends - E 0054

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"

    581.2 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

    595.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observations (11)

DistanceCodeObservation
0MWL
0MGOCONNECTION AT THE MH 9 O'CLOCK ACTIVE
6MGOMagnesium hydroxide coating start
581.2TBA
596.6MGOMagnesium hydroxide coating finish
6MGOCOCKROACHES
600AMHE 0054
0MWM
595.9SAP
6SAP
0AMHE 0055

Properties (5)

additional_info
SC301939
custom_field_two
4
customer
LACSD
datetime
2016-10-20T23:34:00-07:00
sewer_category