Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 10, 2016, 10:23 AM
  • 02 1797_02 1796_10102016_032625.mp4

Date
10/10/2016
W/O
596913
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00292
PipeID
P04142
Time
3:23 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3426
Sewer Name
02 MONTEREY PARK RELIEF TRUNK
City
MONEREY PARK
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_596913_TV02215_OCT2016
Material
NRCP
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
02 1797
Downstream MH
02 1796
Dir. of Survey
Downstream
Length Surveyed
288.1 ft.
Total Length
288.2 ft.
Structural Index
3
Structural Quick
4G3K
Structural Rating
337
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
337
Pipe schematic from manhole 02 1797 to 02 1796
MH: 02 1797MH: 02 1796downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 17970.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"12.4 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: NO13 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"14.6 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES46.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"58.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"78.1 ft. FM - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES88.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start88.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"100.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"121.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"149 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"166.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"191.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"193.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"235.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"250.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"263.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"281.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"285.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish285.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish288.2 ft. AMH - Downstream Manhole, Survey Ends - 02 1796

Observation photos (5)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    0.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: NO

    12.4 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: NO

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    14.6 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    78.1 ft. - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    88.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (26)

DistanceCodeObservation
0MWL
281.4TF
0.2SAV
88.5FM
288.2AMH02 1796
88.5TF
193.7TF
285.3SAV
250.7TF
285.3FM
14.6FL
149TF
166.9TF
78.1FM
235.7TF
121.5TF
46.5TF
58.4TF
263.6TB
12.4FL
7.6TF
100.6TF
0MWM
191.5TF
13TF
0AMH02 1797

Properties (5)

additional_info
SC303460
custom_field_two
2
customer
LACSD
datetime
2016-10-10T03:23:13-07:00
sewer_category
Gravity