- Date
- 01/23/2017
- W/O
- 613646
- Weather
- Light Rain
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00793
- PipeID
- P16518
- Time
- 2:34 AM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4086
- Sewer Name
- 22 CAMERON TRUNK, SECTS 1,2,&3
- City
- WEST COVINA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 35
- Purpose
- Routine Assessment
- Project
- WO_613646_TV22160_JAN2017
- Material
- NRCP
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 22 0236
- Downstream MH
- 22 0235
- Dir. of Survey
- Downstream
- Length Surveyed
- 420.6 ft.
- Total Length
- 420.6 ft.
- Structural Index
- 3
- Structural Quick
- 3R00
- Structural Rating
- 282
- O&M Index
- 2
- O&M Quick
- 4A3B
- O&M Rating
- 253
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 535
Pipe schematic from manhole 22 0236 to 22 0235 Observation photos (4)

2.2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2.2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

28 ft. - Water Level, Sag in pipe, 45 %of cross sectional area, Start

178.8 ft. - General Photograph