Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 20, 2016, 07:32 AM
  • E 0059_E 0058_20161020_021009.mp4

Date
10/20/2016
W/O
597390
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00028
PipeID
P11289
Time
12:32 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3859
Sewer Name
E JOINT OUTFALL E - UNIT 2
City
LYNWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_597390_TV01088_OCT2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
54 in.
Upstream MH
E 0059
Downstream MH
E 0058
Dir. of Survey
Downstream
Length Surveyed
372.7 ft.
Total Length
372.7 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
174
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
178
Pipe schematic from manhole E 0059 to E 0058
MH: E 0059MH: E 0058downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - E 00590 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. MGO - General Observation - Magnesium hydroxide coating start84.7 ft. SAP - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES, Start274.8 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 8"372.7 ft. MSA - Survey Abandoned - SEVERE DEBRIS 25%372.7 ft. OBN - Obstacles Construction Debris, 25 %of cross sectional area, from 04 to 08 o'clock - NOT VISIBLE372.7 ft. SAP - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish372.7 ft. MGO - General Observation - Magnesium hydroxide coating finish

Observation photos (2)

  • Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    84.7 ft. - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 8"

    274.8 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 8"

Observations (10)

DistanceCodeObservation
0MWL
0AMHE 0059
372.7MSASEVERE DEBRIS 25%
84.7SAP
372.7OBNNOT VISIBLE
372.7SAP
2MGOMagnesium hydroxide coating start
372.7MGOMagnesium hydroxide coating finish
274.8TBA
0MWM

Properties (5)

additional_info
SC301938
custom_field_two
3
customer
LACSD
datetime
2016-10-20T00:32:26-07:00
sewer_category
Gravity