- Date
- 10/27/2016
- W/O
- 597390
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00028
- PipeID
- P07612
- Time
- 2:39 AM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3865
- Sewer Name
- E JOINT OUTFALL E - UNIT 2
- City
- COMPTON
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 19
- Purpose
- Routine Assessment
- Project
- WO_597390_TV01088_OCT2016
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 54 in.
- Width
- 54 in.
- Upstream MH
- E 0029
- Downstream MH
- E 0028
- Dir. of Survey
- Downstream
- Length Surveyed
- 8.3 ft.
- Total Length
- 8.3 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole E 0029 to E 0028 Observation photos (4)

2.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

8.3 ft. - Survey Abandoned - SEVERE DEBRIS 25%

8.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

8.3 ft. - Obstacles Construction Debris, 25 %of cross sectional area, from 04 to 08 o'clock