Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 28, 2016, 08:29 AM
  • C 0672_C 0671 _28092016_012939.mp4

Date
09/28/2016
W/O
592158
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01114
PipeID
P23941
Time
1:29 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3591
Sewer Name
C JOINT OUTFALL C - UNIT 3H
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
WO_592158_TV29041_SEP2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
C 0672
Downstream MH
C 0671
Dir. of Survey
Downstream
Length Surveyed
124.5 ft.
Total Length
124.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2400
O&M Rating
8
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole C 0672 to C 0671
MH: C 0672MH: C 0671downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 06720 ft. MWM - Water Mark, 10 %of cross sectional area44.8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"45.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"103.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start121.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish124.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK124.5 ft. AMH - Downstream Manhole, Survey Ends - C 0671

Observation photos (2)

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    44.8 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    103.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
44.8TB
121.7DAGS
0MWL
124.5MGOCONNECTION AT MH 9 O'CLOCK
124.5AMHC 0671
103.2DAGS
0AMHC 0672
0MWM
45.2TFC

Properties (6)

additional_info
SC306186
custom_field_two
4
customer
LACSD
datetime
2016-09-28T01:29:06-07:00
sewer_category
Gravity
year_laid
37482