Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 28, 2016, 07:35 AM
  • C 0673A_C 0673 _28092016_003703.mp4

Date
09/28/2016
W/O
592158
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01114
PipeID
P23943
Time
12:35 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3591
Sewer Name
C JOINT OUTFALL C - UNIT 3H
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
WO_592158_TV29041_SEP2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
C 0673A
Downstream MH
C 0673
Dir. of Survey
Downstream
Length Surveyed
278.2 ft.
Total Length
278.2 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
162
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
162
Pipe schematic from manhole C 0673A to C 0673
MH: C 0673AMH: C 0673downstream0 ft. AMH - Upstream Manhole, Survey Begins - C 0673A0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area3.3 ft. CM - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES9.7 ft. CM - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES15.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start42 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"136 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"242.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"273 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish278.2 ft. AMH - Downstream Manhole, Survey Ends - C 0673

Observation photos (3)

  • Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    3.3 ft. - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    9.7 ft. - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    15.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
42TF
136TF
242.2TF
0AMHC 0673A
15.5CM
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
0MWM
9.7CM
278.2AMHC 0673
3.3CM
273CM

Properties (6)

additional_info
SC306186
custom_field_two
3
customer
LACSD
datetime
2016-09-28T00:35:55-07:00
sewer_category
Gravity
year_laid
37482