Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 28, 2016, 06:20 AM
  • C 0678_C 0677 _27092016_232232.mp4

Date
09/27/2016
W/O
592158
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01114
PipeID
P23947
Time
11:20 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3591
Sewer Name
C JOINT OUTFALL C - UNIT 3H
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
WO_592158_TV29041_SEP2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
C 0677
Downstream MH
C 0678
Dir. of Survey
Upstream
Length Surveyed
333.2 ft.
Total Length
333.2 ft.
Structural Index
2
Structural Quick
2300
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole C 0677 to C 0678
MH: C 0677MH: C 0678upstream0 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - C 06780 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK78.6 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES174.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"218.7 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES245.6 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES295.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"333.2 ft. MWL - Water Level, 5 %of cross sectional area333.2 ft. MWM - Water Mark, 10 %of cross sectional area333.2 ft. AMH - Downstream Manhole, Survey Begins - C 0677

Observation photos (3)

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    87.6 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    114.5 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    254.6 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
158.8TF
333.2MGOCONNECTION AT MH 12 O'CLOCK
0MWL
254.6CL
333.2MGOCONNECTION AT MH 3 O'CLOCK
37.7TF
0MWM
0AMHC 0677
333.2AMHC 0678
333.2MGOCONNECTION AT MH 9 O'CLOCK
87.6CL
114.5CL

Properties (6)

additional_info
SC306186
custom_field_two
4
customer
LACSD
datetime
2016-09-27T23:20:44-07:00
sewer_category
Gravity
year_laid
37482