Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 28, 2016, 07:00 AM
  • C 0676_C 0675 _28092016_000031.mp4

Date
09/28/2016
W/O
592158
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01114
PipeID
P23945
Time
12:00 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3591
Sewer Name
C JOINT OUTFALL C - UNIT 3H
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
WO_592158_TV29041_SEP2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
C 0676
Downstream MH
C 0675
Dir. of Survey
Downstream
Length Surveyed
326.3 ft.
Total Length
326.3 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
165
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
165
Pipe schematic from manhole C 0676 to C 0675
MH: C 0676MH: C 0675downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 06760 ft. MWM - Water Mark, 5 %of cross sectional area37.8 ft. CM - Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES41.5 ft. CM - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES52.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start93.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"253.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"320 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish326.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK326.3 ft. AMH - Downstream Manhole, Survey Ends - C 0675

Observation photos (3)

  • Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

    37.8 ft. - Crack Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

    41.5 ft. - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    52.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
93.7TF
326.3MGOCONNECTION AT MH 3 O'CLOCK
326.3AMHC 0675
52.6CM
253.3TF
320CM
37.8CM
0MWL
41.5CM
0AMHC 0676
0MWM

Properties (6)

additional_info
SC306186
custom_field_two
3
customer
LACSD
datetime
2016-09-28T00:00:26-07:00
sewer_category
Gravity
year_laid
37482