Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 19, 2016, 09:55 PM
  • 22 0907_22 0906 _09232016_014337.mp4

Date
08/19/2016
W/O
1576257
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00799
PipeID
P17278
Time
2:55 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3766
Sewer Name
22 CONEY TRUNK, SECTS 2&3
City
AZUSA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
11
Purpose
Routine Assessment
Project
WO_592094_TV22030_SEP2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
22 0907
Downstream MH
22 0906
Dir. of Survey
Downstream
Length Surveyed
272.3 ft.
Total Length
272.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2G00
O&M Rating
84
Overall Index
2
Overall Quick
Overall Rating
84
Pipe schematic from manhole 22 0907 to 22 0906
MH: 22 0907MH: 22 0906downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 09070 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area59.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start270 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish272.3 ft. AMH - Downstream Manhole, Survey Ends - 22 0906

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    59.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
270DAGS
59.1DAGS
0AMH22 0907
0MWM
272.3AMH22 0906
0MWL

Properties (5)

additional_info
SC306301
custom_field_two
4
customer
LACSD
datetime
2016-08-19T14:55:41-07:00
sewer_category