Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 19, 2016, 09:53 PM
  • 22 0884_22 0883 _09262016_050312.mp4

Date
08/19/2016
W/O
1576257
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00799
PipeID
P17253
Time
2:53 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3767
Sewer Name
22 CONEY TRUNK, SECTS 2&3
City
AZUSA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
11
Purpose
Routine Assessment
Project
WO_592094_TV22030_SEP2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
22 0884
Downstream MH
22 0883
Dir. of Survey
Downstream
Length Surveyed
21.6 ft.
Total Length
21.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2400
O&M Rating
8
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 22 0884 to 22 0883
MH: 22 0884MH: 22 0883downstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start0 ft. AMH - Upstream Manhole, Survey Begins - 22 08840 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area19.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish21.6 ft. AMH - Downstream Manhole, Survey Ends - 22 0883

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0DAGS
0AMH22 0884
21.6AMH22 0883
19.1DAGS
0MWM
0MWL

Properties (5)

additional_info
SC306302
custom_field_two
4
customer
LACSD
datetime
2016-08-19T14:53:00-07:00
sewer_category
Gravity