Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 6, 2016, 10:18 AM
  • 22 0545_22 0544 _09062016_031929.mp4

Date
09/06/2016
W/O
592045
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00791
PipeID
P16887
Time
3:18 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3423
Sewer Name
22 BEN LOMOND TRUNK
City
GLENDORA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
20
Purpose
Routine Assessment
Project
WO_592045_TV22006_SEP2016
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0545
Downstream MH
22 0544
Dir. of Survey
Downstream
Length Surveyed
82.2 ft.
Total Length
82.2 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
45
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
47
Pipe schematic from manhole 22 0545 to 22 0544
MH: 22 0545MH: 22 0544downstream0 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 100 ft. MGO - General Observation - CONNECTION AT MH 30 ft. AMH - Upstream Manhole, Survey Begins - 22 05450 ft. MWL - Water Level, 10 %of cross sectional area2.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"73 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"78.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish82.2 ft. AMH - Downstream Manhole, Survey Ends - 22 054482.2 ft. VC - Vermin Cockroach

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    8 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    73 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

Observations (12)

DistanceCodeObservation
82.2AMH22 0544
0VC
8TFC
0MWM
82.2VC
0MGOCONNECTION AT MH 10
0MGOCONNECTION AT MH 3
73TFC
0AMH22 0545
78.6SAV
0MWL
2.8SAV

Properties (5)

additional_info
SC305986
custom_field_two
3
customer
LACSD
datetime
2016-09-06T03:18:37-07:00
sewer_category
Gravity