Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 30, 2016, 10:42 AM
  • 22 0551_22 0550 _08302016_034327.mp4

Date
08/30/2016
W/O
592045
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00791
PipeID
P16893
Time
3:42 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3422
Sewer Name
22 BEN LOMOND TRUNK
City
GLENDORA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
20
Purpose
Routine Assessment
Project
WO_592045_TV22006_SEP2016
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0551
Downstream MH
22 0550
Dir. of Survey
Downstream
Length Surveyed
449 ft.
Total Length
449 ft.
Structural Index
3
Structural Quick
3Q00
Structural Rating
267
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
269
Pipe schematic from manhole 22 0551 to 22 0550
MH: 22 0551MH: 22 0550downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. AMH - Upstream Manhole, Survey Begins - 22 05510 ft. MWL - Water Level, 15 %of cross sectional area2 ft. MGO - General Observation - MAG. H.OX 60% START2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SMALL AMOUNT7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"93 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"150.3 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"219.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"277 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"301.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"326 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"350.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"375 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4", 4"399.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"425.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"445 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish446.1 ft. MGO - General Observation - MAG. H.OX 50% FINISH449 ft. AMH - Downstream Manhole, Survey Ends - 22 0550449 ft. VC - Vermin Cockroach

Observation photos (11)

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    7 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    93 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"

    150.3 ft. - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    219.9 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    277 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    301.2 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    326 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"

    350.8 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4", 4"

    375 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4", 4"

  • Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"

    399.9 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    425.1 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

Observations (21)

DistanceCodeObservation
0MWM
449AMH22 0550
2MGOMAG. H.OX 60% START
0VC
93TF
219.9TF
2SAVSMALL AMOUNT
399.9TFC
326TFC
350.8TFC
301.2TFC
0AMH22 0551
0MWL
375TFC
449VC
277TF
446.1MGOMAG. H.OX 50% FINISH
150.3TFA
425.1TFC
445SAV
7TF

Properties (5)

additional_info
SC305984
custom_field_two
3
customer
LACSD
datetime
2016-08-30T03:42:55-07:00
sewer_category
Gravity