Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 30, 2016, 08:38 AM
  • 22 0555_22 0554 _08302016_013810.mp4

Date
08/30/2016
W/O
592045
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00791
PipeID
P16897
Time
1:38 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3422
Sewer Name
22 BEN LOMOND TRUNK
City
GLENDORA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
21
Purpose
Routine Assessment
Project
WO_592045_TV22006_SEP2016
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0555
Downstream MH
22 0554
Dir. of Survey
Downstream
Length Surveyed
163.3 ft.
Total Length
163.3 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
48
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
49
Pipe schematic from manhole 22 0555 to 22 0554
MH: 22 0555MH: 22 0554downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 05550 ft. MWM - Water Mark, 30 %of cross sectional area15.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"76.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"83.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: NO83.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start92.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"149.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"154 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"159.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish163.3 ft. AMH - Downstream Manhole, Survey Ends - 22 0554163.3 ft. MGO - General Observation - CONNECTION AT MH 3163.3 ft. VC - Vermin Cockroach

Observation photos (7)

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    15.6 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    76.8 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: NO

    83.6 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    83.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    92.8 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    149.8 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    154 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"

Observations (14)

DistanceCodeObservation
154TFC
83.6FL
149.8TF
163.3AMH22 0554
159.5SAV
0MWL
0AMH22 0555
0MWM
163.3MGOCONNECTION AT MH 3
83.6SAV
92.8TF
15.6TF
163.3VC
76.8TFC

Properties (5)

additional_info
SC305984
custom_field_two
3
customer
LACSD
datetime
2016-08-30T01:38:03-07:00
sewer_category