Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 4, 2017, 10:20 AM
  • 02 1718_02 1717_01042017_022038.mp4

Date
01/04/2017
W/O
613349
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00289
PipeID
P18882
Time
2:20 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4049
Sewer Name
02 MONTEREY PARK EXTENSION TRUNK
City
MONTEREY PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
06
Purpose
Routine Assessment
Project
WO_613349_TV02103_JAN2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1718
Downstream MH
02 1717
Dir. of Survey
Downstream
Length Surveyed
218.5 ft.
Total Length
218.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2H00
O&M Rating
88
Overall Index
2
Overall Quick
Overall Rating
88
Pipe schematic from manhole 02 1718 to 02 1717
MH: 02 1718MH: 02 1717downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 17182 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start14.2 ft. OBR - Obstacles Rocks, 10 %of cross sectional area, at 06 o'clock59.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"126.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"178.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"216.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish216.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE218.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1717

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    216.8 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (11)

DistanceCodeObservation
178.3TFA
126.4TFA
0MWM
0MWL
14.2OBR
2DAGS
216.8DAGS
218.5AMH02 1717
0AMH02 1718
59.8TFA
216.8MGOCOCKROACHES IN MANHOLE

Properties (5)

additional_info
SC306447
custom_field_two
4
customer
LACSD
datetime
2017-01-04T02:20:10-08:00