- Date
- 10/05/2016
- W/O
- 592155
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00652
- PipeID
- P13317
- Time
- 11:52 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3775
- Sewer Name
- 16 CHAPEL AVENUE TRUNK, SECTION 1
- City
- SOUTH PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- WO_592155_TV16001_SEP2016
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 16 0275
- Downstream MH
- 16 0274
- Dir. of Survey
- Downstream
- Length Surveyed
- 218.4 ft.
- Total Length
- 218.4 ft.
- Structural Index
- 3
- Structural Quick
- 3600
- Structural Rating
- 18
- O&M Index
- 2
- O&M Quick
- 2I00
- O&M Rating
- 102
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 120
Pipe schematic from manhole 16 0275 to 16 0274 Observation photos (3)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

25 ft. - Water Level, Sag in pipe, 50 %of cross sectional area, Start

34.1 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start