- Date
- 10/03/2016
- W/O
- 591626
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00639
- PipeID
- P13058
- Time
- 3:55 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3772
- Sewer Name
- 16 ALLEN AVENUE TRUNK, SECTS 1,2,&4
- City
- SAN GABRIEL
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 01
- Purpose
- Routine Assessment
- Project
- WO_591626_TV16113_SEP2016
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 16 in.
- Width
- 16 in.
- Upstream MH
- 16 0045
- Downstream MH
- 16 0044
- Dir. of Survey
- Downstream
- Length Surveyed
- 342.6 ft.
- Total Length
- 342.6 ft.
- Structural Index
- 2
- Structural Quick
- 2300
- Structural Rating
- 6
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole 16 0045 to 16 0044 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

61.8 ft. - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

226.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

246.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

342.6 ft. - General Observation - ROACHES IN MH