Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 13, 2016, 10:39 AM
  • 02 1295_02 1294_12132016_025554.mp4

Date
12/13/2016
W/O
607634
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00238
PipeID
P03812
Time
2:39 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3938
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_607634_TV02329_DEC2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1295
Downstream MH
02 1294
Dir. of Survey
Downstream
Length Surveyed
357.2 ft.
Total Length
357.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 02 1295 to 02 1294
MH: 02 1295MH: 02 1294downstream0 ft. VC - Vermin Cockroach, within 8 inches of joint: YES0 ft. AMH - Upstream Manhole, Survey Begins - 02 12950 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 9 O CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area58.9 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start69.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"73.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"78.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"81.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"82.6 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"129.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"152.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"155 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"160.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"186 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"198.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"273.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish273.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"276.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"296.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"302.3 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"312 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"353.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"357.2 ft. AMH - Downstream Manhole, Survey Ends - 02 1294

Observation photos (1)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    58.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (25)

DistanceCodeObservation
276.1TFA
198.9TFA
186TFA
78.3TFC
155TFC
0VC
0AMH02 1295
73.3TFC
353.5TFA
81.3TF
58.9CM
312TFA
357.2AMH02 1294
302.3TBA
160.5TFA
0MWM
296.6TFC
0MGOLATERAL AT MH 9 O CLOCK
129.7TFA
82.6TBA
273.4TFA
0MWL
152.7TFA
69.2TB
273.1CM

Properties (5)

additional_info
SC317682
custom_field_two
3
customer
LACSD
datetime
2016-12-13T02:39:00-08:00
sewer_category
Gravity