- Date
- 10/19/2016
- W/O
- 592160
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00497
- PipeID
- P06731
- Time
- 2:47 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3809
- Sewer Name
- 05 NORTH TORRANCE EXTENSION TRUNK
- City
- TORRANCE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 26
- Purpose
- Routine Assessment
- Project
- WO_592160_TV05263_SEP2016
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 05 1508
- Downstream MH
- 05 1507
- Dir. of Survey
- Downstream
- Length Surveyed
- 239.7 ft.
- Total Length
- 239.7 ft.
- Structural Index
- 2
- Structural Quick
- 2300
- Structural Rating
- 6
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole 05 1508 to 05 1507 Observation photos (4)

2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

89 ft. - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

132.8 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

191.6 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES