Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 11, 2016, 07:01 PM
  • H 0957_H 0956_20160211_121437.mp4

Date
02/11/2016
W/O
552579
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z01005
PipeID
P15370
Time
11:01 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3180
Sewer Name
H JOINT OUTFALL H - UNIT 7C
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Project
WO_552579_TV21022_FEB2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Upstream MH
H 0957
Downstream MH
H 0956
Dir. of Survey
Downstream
Length Surveyed
402.5 ft.
Total Length
402.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4111
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole H 0957 to H 0956
MH: H 0957MH: H 0956downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 09570 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - CAPPED LATERAL AT 9 O' CLOCK AT0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. MGO - General Observation - MAGNEZIUM H.O COATING 50% finish399.6 ft. MGO - General Observation - MAGNEZIUM H.O COATING 50 % finish402.5 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH402.5 ft. VC - Vermin Cockroach402.5 ft. MGO - General Observation - SERVICE LATERAL AT 3 O' CLOCK AT MH402.5 ft. AMH - Downstream Manhole, Survey Ends - H 0960

Observations (10)

DistanceCodeObservation
2MGOMAGNEZIUM H.O COATING 50% finish
0AMHH 0957
402.5MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
0MWM
402.5VC
402.5MGOSERVICE LATERAL AT 3 O' CLOCK AT MH
0MGOCAPPED LATERAL AT 9 O' CLOCK AT
399.6MGOMAGNEZIUM H.O COATING 50 % finish
0MWL
402.5AMHH 0960

Properties (5)

additional_info
SC224994
custom_field_two
4
customer
LACSD
datetime
2016-02-11T11:01:24-08:00
sewer_category