Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 10, 2016, 08:33 PM
Date
02/10/2016
W/O
552579
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z01005
PipeID
P15375
Time
12:33 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3179
Sewer Name
H JOINT OUTFALL H - UNIT 7C
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Project
WO_552579_TV21022_FEB2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Upstream MH
H 0962
Downstream MH
H 0961
Dir. of Survey
Downstream
Length Surveyed
436.4 ft.
Total Length
436.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole H 0962 to H 0961
MH: H 0962MH: H 0961downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 09620 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. MGO - General Observation - MAGNEZIUM H.O COATING 40% start74.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"432.4 ft. MGO - General Observation - MAGNEZIUM H.O COATING 40% finish436.4 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH436.4 ft. AMH - Downstream Manhole, Survey Ends - H 0961

Observations (8)

DistanceCodeObservation
436.4MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
432.4MGOMAGNEZIUM H.O COATING 40% finish
0AMHH 0962
436.4AMHH 0961
2MGOMAGNEZIUM H.O COATING 40% start
0MWM
0MWL
74.3TFA

Properties (5)

additional_info
SC224993
custom_field_two
4
customer
LACSD
datetime
2016-02-10T12:33:40-08:00
sewer_category
GRAVITY