Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 11, 2016, 02:54 PM
  • H 0981_H 0980_20160211_080749.mp4

Date
02/11/2016
W/O
552579
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z01005
PipeID
P15394
Time
6:54 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3180
Sewer Name
H JOINT OUTFALL H - UNIT 7C
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
35
Purpose
Routine Assessment
Project
WO_552579_TV21022_FEB2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Upstream MH
H 0981
Downstream MH
H 0980
Dir. of Survey
Downstream
Length Surveyed
350.3 ft.
Total Length
350.3 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole H 0981 to H 0980
MH: H 0981MH: H 0980downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 09812 ft. MGO - General Observation - MAGNEZIUM H.O COATING 60% start126.4 ft. TBI - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 4", 3"147.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start327.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"349.1 ft. MGO - General Observation - MAGNEZIUM H.O COATING 60% finish349.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish350.3 ft. AMH - Downstream Manhole, Survey Ends - H 0980

Observation photos (2)

  • Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 4", 3"

    126.4 ft. - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 4", 3"

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    147.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

Observations (10)

DistanceCodeObservation
349.1MGOMAGNEZIUM H.O COATING 60% finish
2MGOMAGNEZIUM H.O COATING 60% start
327.3TFA
0MWM
126.4TBI
0MWL
350.3AMHH 0980
349.1SSS
0AMHH 0981
147.8SSS

Properties (5)

additional_info
SC224994
custom_field_two
4
customer
LACSD
datetime
2016-02-11T06:54:07-08:00
sewer_category
GRAVITY