Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 8, 2016, 03:20 PM
  • H 0951_H 0950_20160329_073019.mp4

Date
03/08/2016
W/O
552579
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z01005
PipeID
P20187
Time
7:20 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3219
Sewer Name
H JOINT OUTFALL H - UNIT 7C
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Project
WO_552579_TV21022_FEB2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Upstream MH
H 0950
Downstream MH
H 0951
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
5111
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole H 0950 to H 0951
MH: H 0950MH: H 0951upstream0 ft. MGO - General Observation - UPLEG SIPHON FROM DOWNSTREAM MH0 ft. MSA - Survey Abandoned - DUE TOP SIPHON2 ft. MWM - Water Mark, 100 %of cross sectional area2 ft. VC - Vermin Cockroach, within 8 inches of joint: YES2 ft. AMH - Downstream Manhole, Survey Begins - H 09502 ft. MWL - Water Level, 100 %of cross sectional area

Observation photos (1)

  • Survey Abandoned - DUE TOP SIPHON

    2 ft. - Survey Abandoned - DUE TOP SIPHON

Observations (6)

DistanceCodeObservation
2MGOUPLEG SIPHON FROM DOWNSTREAM MH
0MWM
2MSADUE TOP SIPHON
0VC
0AMHH 0950
0MWL

Properties (5)

additional_info
SC305309
custom_field_two
4
customer
LACSD
datetime
2016-03-08T07:20:23-08:00
sewer_category
SIPHON