- Date
- 02/29/2016
- W/O
- 552579
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z01005
- PipeID
- P15342
- Time
- 1:57 AM
- Certificate
- U-507-03-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3209
- Sewer Name
- H JOINT OUTFALL H - UNIT 7C
- City
- CITY OF INDUSTRY
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 33
- Purpose
- Routine Assessment
- Project
- WO_552579_TV21022_FEB2016
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- H 0929
- Downstream MH
- H 0928
- Dir. of Survey
- Downstream
- Length Surveyed
- 452.1 ft.
- Total Length
- 452.1 ft.
- Structural Index
- 2
- Structural Quick
- 2300
- Structural Rating
- 6
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole H 0929 to H 0928 Observation photos (4)

0 ft. - General Observation - MAG COAT THROUGHOUT PIPE 55%

49.1 ft. - Surface Spalling, at 12 o'clock, within 8 inches of joint: YES

75.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

401.3 ft. - Surface Spalling, at 02 o'clock, within 8 inches of joint: YES