Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 17, 2016, 03:45 PM
  • H 0934_H 0933_20160217_093227.mp4

Date
02/17/2016
W/O
552579
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z01005
PipeID
P15347
Time
7:45 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3182
Sewer Name
H JOINT OUTFALL H - UNIT 7C
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
33
Purpose
Routine Assessment
Project
WO_552579_TV21022_FEB2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Upstream MH
H 0934
Downstream MH
H 0933
Dir. of Survey
Downstream
Length Surveyed
381.1 ft.
Total Length
381.1 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole H 0934 to H 0933
MH: H 0934MH: H 0933downstream0 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH0 ft. AMH - Upstream Manhole, Survey Begins - H 09340 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area54.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start378 ft. MGO - General Observation - MAGNEZIUM H.O COATING 50% finish378 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish381.1 ft. AMH - Downstream Manhole, Survey Ends - H 0933

Observation photos (1)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    54.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
54.4SSS
381.1AMHH 0933
0AMHH 0934
0MWL
0MWM
378MGOMAGNEZIUM H.O COATING 50% finish
378SSS

Properties (5)

additional_info
SC224997
custom_field_two
4
customer
LACSD
datetime
2016-02-17T07:45:50-08:00
sewer_category
SIPHON