Wastewater/Activity/PacpInspection/1.0Nov 4, 2016, 07:01 AM
  • 01 0010_01 0009_04112016_000238.mp4

Date
11/04/2016
W/O
602591
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00209
PipeID
P00674
Time
12:01 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3872
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
16
Purpose
Routine Assessment
Project
WO_602591_TV01050_NOV2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
01 0010
Downstream MH
01 0009
Dir. of Survey
Downstream
Length Surveyed
282.7 ft.
Total Length
282.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 01 0010 to 01 0009
MH: 01 0010MH: 01 0009downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - ROACHES IN MH0 ft. AMH - Upstream Manhole, Survey Begins - 01 00100 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK ACTIVE2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start279 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish282.7 ft. AMH - Downstream Manhole, Survey Ends - 01 0009282.7 ft. MGO - General Observation - ROACHES IN MH

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Finish

    279 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish

Observations (10)

DistanceCodeObservation
282.7AMH01 0009
282.7MGOROACHES IN MH
2.1DAGS
0MWM
0MWL
279DAGS
0MGOROACHES IN MH
0AMH01 0010
0MGOLATERAL AT MH 9 OCLOCK ACTIVE
0MGOLATERAL AT MH 3 OCLOCK ACTIVE

Properties (5)

additional_info
SC305202
custom_field_two
4
customer
LACSD
datetime
2016-11-04T00:01:43-07:00
sewer_category
Gravity