Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 2, 2016, 06:25 AM
  • 01 0016_01 0015_01112016_232633.mp4

Date
11/01/2016
W/O
602591
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00209
PipeID
P00681
Time
11:25 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3870
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
16
Purpose
Routine Assessment
Project
WO_602591_TV01050_NOV2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
01 0016
Downstream MH
01 0015
Dir. of Survey
Downstream
Length Surveyed
390.8 ft.
Total Length
390.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
3
Pipe schematic from manhole 01 0016 to 01 0015
MH: 01 0016MH: 01 0015downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - ROACHES IN MH0 ft. MGO - General Observation - LINING CIPP0 ft. AMH - Upstream Manhole, Survey Begins - 01 00162.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start388 ft. VC - Vermin Cockroach388 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish390.8 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK ACTIVE390.8 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK MADE390.8 ft. AMH - Downstream Manhole, Survey Ends - 01 0015

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Finish

    388 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish

Observations (11)

DistanceCodeObservation
388VC
0MWL
390.8MGOLATERAL AT MH 3 OCLOCK ACTIVE
0MWM
0MGOROACHES IN MH
390.8MGOLATERAL AT MH 9 OCLOCK MADE
0MGOLINING CIPP
390.8AMH01 0015
2.1DAGS
0AMH01 0016
388DAGS

Properties (5)

additional_info
SC301950
custom_field_two
4
customer
LACSD
datetime
2016-11-01T23:25:53-07:00
sewer_category