Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2016, 09:35 AM
  • 02 1121_02 1120 _08112016_014047.mp4

Date
11/08/2016
W/O
602268
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00351
PipeID
P02900
Time
1:35 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3818
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
14
Purpose
Routine Assessment
Project
WO_602268_TV02061_NOV2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1120
Downstream MH
02 1121
Dir. of Survey
Upstream
Length Surveyed
294.1 ft.
Total Length
294.1 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
165
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
165
Pipe schematic from manhole 02 1120 to 02 1121
MH: 02 1120MH: 02 1121upstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED0 ft. AMH - Upstream Manhole, Survey Ends - 02 11210 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED4.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish161.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"204.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"207.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"257.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"261.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"279.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start294.1 ft. MWM - Water Mark, 20 %of cross sectional area294.1 ft. AMH - Downstream Manhole, Survey Begins - 02 1120294.1 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (1)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    14.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MWM
36.6TFC
32.3TFC
86.6TFC
89.9TF
0AMH02 1120
294.1MGOCONNECTION AT MH 9 O'CLOCK CAPPED
0MWL
289.6CM
14.5CM
294.1AMH02 1121
132.9TFC
294.1MGOCONNECTION AT MH 3 O'CLOCK CAPPED

Properties (4)

custom_field_two
3
customer
LACSD
datetime
2016-11-08T01:35:01-08:00
sewer_category
Gravity