Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2016, 08:45 AM
  • 01 0520A_01 0520_08112016_004635.mp4

Date
11/08/2016
W/O
602233
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00206
PipeID
P01005
Time
12:45 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3874
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
City
LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_602233_TV01017_NOV2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0520A
Downstream MH
01 0520
Dir. of Survey
Downstream
Length Surveyed
148.4 ft.
Total Length
148.4 ft.
Structural Index
3
Structural Quick
4121
Structural Rating
6
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 01 0520A to 01 0520
MH: 01 0520AMH: 01 0520downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - ROACHES IN MH0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 01 0520A2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.6 ft. FM - Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES5.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"50 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"52.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"54.9 ft. VC - Vermin Cockroach85.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"89 ft. CS - Crack Spiral, from 12 to 02 o'clock, within 8 inches of joint: YES100 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"114.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"145 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish148.4 ft. AMH - Downstream Manhole, Survey Ends - 01 0520148.4 ft. MGO - General Observation - ROACHES IN MH

Observation photos (10)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    3.6 ft. - Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    5.6 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    50 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    52.7 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    85.2 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Crack Spiral, from 12 to 02 o'clock, within 8 inches of joint: YES

    89 ft. - Crack Spiral, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    100 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    114.2 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Finish

    145 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observations (18)

DistanceCodeObservation
3.6FM
0MWM
5.6TFC
145DAGS
2.2DAGS
85.2TF
100TFA
148.4AMH01 0520
0MGOROACHES IN MH
0MWL
52.7TFC
148.4MGOROACHES IN MH
114.2TFC
89CS
0MGOLATERAL AT MH 3 OCLOCK ACTIVE
50TFA
54.9VC
0AMH01 0520A

Properties (5)

additional_info
SC305204
custom_field_two
3
customer
LACSD
datetime
2016-11-08T00:45:18-08:00
sewer_category
Gravity