Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2016, 08:58 AM
  • 01 0520_01 0519_08112016_005839.mp4

Date
11/08/2016
W/O
602233
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00206
PipeID
P01004
Time
12:58 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3874
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_602233_TV01017_NOV2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0520
Downstream MH
01 0519
Dir. of Survey
Downstream
Length Surveyed
304.9 ft.
Total Length
304.9 ft.
Structural Index
3
Structural Quick
5141
Structural Rating
16
O&M Index
2
O&M Quick
2311
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
23
Pipe schematic from manhole 01 0520 to 01 0519
MH: 01 0520MH: 01 0519downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 05200 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - ROACHES IN MH2.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.3 ft. CC - Crack Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES4.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"7.7 ft. B - Broken, from 09 to 11 o'clock, within 8 inches of joint: YES - BROKEN WITH REPAIR VISIBLE13.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"39.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"48.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"55.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES78.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"81.9 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"104.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"110.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"131.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"145.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"169.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"177.7 ft. RFL - Roots Fine Lateral, at 10 o'clock177.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"207.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"210 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - BROKEN INSIDE238.3 ft. CM - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES251.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"254.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS INSIDE283.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"300 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES301.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish304.9 ft. AMH - Downstream Manhole, Survey Ends - 01 0519304.9 ft. MGO - General Observation - ROACHES IN MH

Observation photos (23)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES

    3.3 ft. - Crack Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    4.7 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Broken, from 09 to 11 o'clock, within 8 inches of joint: YES - BROKEN WITH REPAIR VISIBLE

    7.7 ft. - Broken, from 09 to 11 o'clock, within 8 inches of joint: YES - BROKEN WITH REPAIR VISIBLE

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    13.2 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    39.9 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    48.6 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    55.3 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    78.2 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    81.9 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    104.7 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    110.5 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    131.1 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    145.4 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    169.3 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    177.7 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    207.4 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - BROKEN INSIDE

    210 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - BROKEN INSIDE

  • Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    238.3 ft. - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    251.6 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS INSIDE

    254.2 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS INSIDE

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    283.6 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    300 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (31)

DistanceCodeObservation
0MWL
207.4TFC
301.9DAGS
254.2TFDEBRIS INSIDE
283.6TFA
104.7TFC
7.7BBROKEN WITH REPAIR VISIBLE
39.9TFC
177.7RFL
0AMH01 0520
4.7TFA
145.4TFA
304.9AMH01 0519
110.5TFA
177.7TFA
0MWM
48.6TFA
3.3CC
78.2TFC
0MGOROACHES IN MH
304.9MGOROACHES IN MH
300FM
169.3TFC
81.9TBA
2.4DAGS
13.2TF
238.3CM
55.3CM
210TFDBROKEN INSIDE
131.1TFC
251.6TFA

Properties (5)

additional_info
SC305204
custom_field_two
3
customer
LACSD
datetime
2016-11-08T00:58:23-08:00
sewer_category