Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 2, 2016, 08:40 AM
  • 14 0540_14 0539_02032016_004028.mp4

Date
03/02/2016
W/O
552346
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00588
PipeID
P18631
Time
12:40 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3273
Sewer Name
14 35TH STREET WEST TRUNK
City
PALMDALE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
11
Purpose
Routine Assessment
Project
WO_552346_TV14042_FEB2016
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
14 0540
Downstream MH
14 0539
Dir. of Survey
Downstream
Length Surveyed
502.7 ft.
Total Length
502.7 ft.
Structural Index
3
Structural Quick
3S00
Structural Rating
300
O&M Index
2
O&M Quick
2S00
O&M Rating
200
Overall Index
3
Overall Quick
Overall Rating
500
Pipe schematic from manhole 14 0540 to 14 0539
MH: 14 0540MH: 14 0539downstream0 ft. AMH - Upstream Manhole, Survey Begins - 14 05400 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - MAG COATING 60%501 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish501 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish502.7 ft. AMH - Downstream Manhole, Survey Ends - 14 0539

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
2SAV
501SAV
501DAGS
0AMH14 0540
2DAGS
502.7AMH14 0539
0MWL
2MGOMAG COATING 60%
0MWM

Properties (5)

additional_info
SC225497
custom_field_two
3
customer
LACSD
datetime
2016-03-02T00:40:12-08:00
sewer_category