08 0480_08 0479 _08302016_232200.mp4
9.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start
39.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
44.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
114.4 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS
114.4 ft. - Roots Medium Lateral, from 07 to 11 o'clock, 15 %, within 8 inches of joint: YES
190.5 ft. - General Observation - COCKROACHES IN MANHOLE
| Distance | Code | Observation |
|---|---|---|
| 59.4 | TFC | — |
| 0 | AMH | 08 0479 |
| 188.6 | DAGS | — |
| 54.7 | TFC | — |
| 190.5 | MGO | COCKROACHES IN MANHOLE |
| 44.3 | CM | — |
| 190.5 | AMH | 08 0480 |
| 190.5 | MGO | CAPPED CONNECTION AT MH 9 O'CLOCK |
| 183.8 | CM | — |
| 114.4 | TFD | ROOTS |
| 114.4 | RML | — |
| 0 | MWL | — |
| 0 | MWM | — |
| 13.4 | TFC | — |
| 9.6 | DAGS | — |
| 39.7 | CM | — |
| 164.7 | TFC | — |