08 0230_08 0229 _08312016_235331.mp4
2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
9.5 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES
9.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
87 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES
290.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES
353.1 ft. - General Observation - COCKROACHES IN MANHOLE
| Distance | Code | Observation |
|---|---|---|
| 250 | TFC | — |
| 350.4 | CM | — |
| 350.4 | DAGS | — |
| 0 | MGO | ACTIVE CONNECTION AT MH 3 O'CLOCK |
| 0 | AMH | 08 0230 |
| 2 | DAE | — |
| 9.5 | CL | — |
| 353.1 | MGO | CAPPED CONNECTION AT MH 9 O'CLOCK |
| 353.1 | MGO | COCKROACHES IN MANHOLE |
| 88.3 | TFA | — |
| 2 | DAGS | — |
| 34.8 | TFC | — |
| 353.1 | AMH | 08 0229 |
| 290.7 | DAGS | — |
| 185.8 | DAGS | — |
| 87 | DAGS | — |
| 0 | MWL | — |
| 350.4 | DAE | — |
| 0 | MWM | — |
| 9.9 | CM | — |
| 186.8 | TFA | — |
| 291.3 | TFA | — |