Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 14, 2016, 08:57 AM
  • 02 1868_02 1867_20160114_011837.mp4

Date
01/14/2016
W/O
547457
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00246
PipeID
P04226
Time
12:57 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3156
Sewer Name
02 DOUGLAS AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_547457_TV02192_JAN2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
02 1868
Downstream MH
02 1867
Dir. of Survey
Downstream
Length Surveyed
353.7 ft.
Total Length
353.7 ft.
Structural Index
4
Structural Quick
4L00
Structural Rating
268
O&M Index
2
O&M Quick
4112
O&M Rating
6
Overall Index
4
Overall Quick
Overall Rating
274
Pipe schematic from manhole 02 1868 to 02 1867
MH: 02 1868MH: 02 1867downstream0 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK CAPPED0 ft. AMH - Upstream Manhole, Survey Begins - 02 18683.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES21 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start75.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"88.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"113.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"136.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"156.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"185 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"195.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"212.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"233.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"271.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"274.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"281.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"322.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"353.4 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK353.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish353.7 ft. VC - Vermin Cockroach353.7 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK CAPPED353.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1867

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    3.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    21 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (26)

DistanceCodeObservation
156.9TF
353.7VC
0MGOLATERAL AT MH 9 OCLOCK
233.5TF
281.8TF
0MWM
75.9TF
88.4TF
353.4MGOLATERAL AT MH 9 OCLOCK
353.4FM
3.4FM
353.7MGOLATERAL AT MH 3 OCLOCK CAPPED
271.5TF
21FM
0MWL
212.9TF
353.7AMH02 1867
113.7TF
274.2TF
136.6TF
322.3TF
185TF
0VC
0MGOLATERAL AT MH 3 OCLOCK CAPPED
0AMH02 1868
195.1TF

Properties (5)

additional_info
SC224967
custom_field_two
2
customer
LACSD
datetime
2016-01-14T00:57:38-08:00
sewer_category
GRAVITY