- Date
- 01/13/2016
- W/O
- 547457
- Weather
- Very Dry
- Operator/Surveyor
- N.ZAHREDDINE
- Sewer ID
- Z00246
- PipeID
- P04232
- Time
- 11:06 PM
- Certificate
- U-109-7948
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3156
- Sewer Name
- 02 DOUGLAS AVENUE TRUNK
- City
- LOS ANGELES
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- WO_547457_TV02192_JAN2016
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 02 1874
- Downstream MH
- 02 1873
- Dir. of Survey
- Downstream
- Length Surveyed
- 415.9 ft.
- Total Length
- 415.9 ft.
- Structural Index
- 4
- Structural Quick
- 5141
- Structural Rating
- 11
- O&M Index
- 1
- O&M Quick
- 1200
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole 02 1874 to 02 1873 Observation photos (3)

87 ft. - Fracture Circumferential, from 04 to 05 o'clock, within 8 inches of joint: YES

309.3 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

319.9 ft. - Hole, from 09 to 11 o'clock, within 8 inches of joint: YES - POSSIBLE REPAIR BEHIND HOLE