Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 6, 2016, 11:29 AM
  • 22 0237_22 0236_20160106_044410.mp4

Date
01/06/2016
W/O
547395
Weather
Damp
Operator/Surveyor
R.VARGAS
Sewer ID
Z00793
PipeID
P16519
Time
3:29 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3026
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
35
Purpose
Routine Assessment
Project
WO_547395_TV22016_JAN2016
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0237
Downstream MH
22 0236
Dir. of Survey
Downstream
Length Surveyed
303.7 ft.
Total Length
303.7 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
2114
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 22 0237 to 22 0236
MH: 22 0237MH: 22 0236downstream0 ft. MGO - General Observation - LATERAL AT MH 3 O'CLOCK ACTIVE0 ft. VC - Vermin Cockroach0 ft. MGO - General Observation - LATERAL AT MH 9 O'CLOCK ACTIVE0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 02372.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.6 ft. MGO - General Observation - MAGNESIUM H.O. START2.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start48.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"51.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"84.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4" - DEBRIS INSIDE133.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"159.9 ft. RFJ - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES181.7 ft. VC - Vermin Cockroach181.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"200.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"267.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"300.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish300.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish300.8 ft. MGO - General Observation - MAGNESIUM H.O. FINISH303.7 ft. AMH - Downstream Manhole, Survey Ends - 22 0236303.7 ft. MGO - General Observation - LATERAL AT MH 9 O'CLOCK ACTIVE303.7 ft. VC - Vermin Cockroach

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (24)

DistanceCodeObservation
303.7AMH22 0236
303.7MGOLATERAL AT MH 9 O'CLOCK ACTIVE
0MGOLATERAL AT MH 3 O'CLOCK ACTIVE
181.7VC
267.3TFC
303.7VC
159.9RFJ
200.2TFC
300.8SAV
300.8DAGS
0VC
300.8MGOMAGNESIUM H.O. FINISH
51.1TFC
2.6SAV
181.7TFC
0MGOLATERAL AT MH 9 O'CLOCK ACTIVE
133.6TFC
48.3TFC
0MWM
0MWL
2.6MGOMAGNESIUM H.O. START
84.6TFCDEBRIS INSIDE
0AMH22 0237
2.6DAGS

Properties (5)

additional_info
SC224619
custom_field_two
3
customer
LACSD
datetime
2016-01-06T03:29:39-08:00
sewer_category
GRAVITY