Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 6, 2016, 10:31 AM
  • 22 0238_22 0237_20160106_041720.mp4

Date
01/06/2016
W/O
547395
Weather
Damp
Operator/Surveyor
R.VARGAS
Sewer ID
Z00793
PipeID
P16520
Time
2:31 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3026
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
35
Purpose
Routine Assessment
Project
WO_547395_TV22016_JAN2016
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0238
Downstream MH
22 0237
Dir. of Survey
Downstream
Length Surveyed
381 ft.
Total Length
381 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
2112
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole 22 0238 to 22 0237
MH: 22 0238MH: 22 0237downstream0 ft. MGO - General Observation - LATERAL AT MH 3 O'CLOCK ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 22 02380 ft. VC - Vermin Cockroach0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2.1 ft. MGO - General Observation - MAGNESIUM H.O. START2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start45.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"90.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"94 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"115.1 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4"142.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"191.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"209.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"249.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"300.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"325 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"349.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"377.2 ft. MGO - General Observation - MAGNESIUM H.O. FINISH377.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish377.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish381 ft. VC - Vermin Cockroach381 ft. MGO - General Observation - LATERAL AT MH 9 O'CLOCK ACTIVE381 ft. MGO - General Observation - LATERAL AT MH 3 O'CLOCK ACTIVE381 ft. AMH - Downstream Manhole, Survey Ends - 22 0237

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

    377.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observations (26)

DistanceCodeObservation
0MGOLATERAL AT MH 3 O'CLOCK ACTIVE
45.2TFC
325TF
381VC
0AMH22 0238
90.7TF
0VC
142.4TFC
381MGOLATERAL AT MH 9 O'CLOCK ACTIVE
349.4TFC
377.2MGOMAGNESIUM H.O. FINISH
94TFA
381MGOLATERAL AT MH 3 O'CLOCK ACTIVE
0MWL
300.8TFC
0MWM
377.3SAV
249.1TFA
2.1MGOMAGNESIUM H.O. START
2.1DAGS
115.1TF
2.1SAV
191.5TFC
209.3TFC
381AMH22 0237
377.3DAGS

Properties (5)

additional_info
SC224619
custom_field_two
3
customer
LACSD
datetime
2016-01-06T02:31:59-08:00
sewer_category