Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 31, 2015, 07:57 AM
  • 22 0285_22 0284_20151231_001025.mp4

Date
12/30/2015
W/O
547382
Weather
Heavy Rain
Operator/Surveyor
R.VARGAS
Sewer ID
Z00793
PipeID
P16571
Time
11:57 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3021
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
WO_547382_TV22014_JAN2016
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0284
Downstream MH
22 0285
Dir. of Survey
Upstream
Length Surveyed
257.4 ft.
Total Length
257.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2212
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 22 0284 to 22 0285
MH: 22 0284MH: 22 0285upstream0 ft. MGO - General Observation - LATERAL AT MH 9 O'CLOCK ACTIVE0 ft. VC - Vermin Cockroach0 ft. AMH - Upstream Manhole, Survey Ends - 22 02852.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.5 ft. MGO - General Observation - MAGNESIUM H.O. FINISH2.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish6.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"8.5 ft. TBA - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: YES, 4"40.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"52.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"121.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"146.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"190.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"206.5 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - CRACK INSIDE231.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"255.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start255.3 ft. MGO - General Observation - MAGNESIUM H.O. START255.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start257.4 ft. MWL - Water Level, 10 %of cross sectional area257.4 ft. AMH - Downstream Manhole, Survey Begins - 22 0284257.4 ft. MWM - Water Mark, 10 %of cross sectional area257.4 ft. VC - Vermin Cockroach

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (22)

DistanceCodeObservation
254.9SAP
2.1DAGS
248.9TBA
254.9MGOMAGNESIUM H.O. FINISH
257.4MGOLATERAL AT MH 9 O'CLOCK ACTIVE
111.3TFA
0MWL
2.1MGOMAGNESIUM H.O. START
257.4VC
257.4AMH22 0285
135.8TFA
26.2TFA
204.9TFC
50.9TFDCRACK INSIDE
0AMH22 0284
250.9TFC
0MWM
216.9TFA
254.9DAGS
66.8TFC
2.1SAP
0VC

Properties (5)

additional_info
SC224613
custom_field_two
3
customer
LACSD
datetime
2015-12-30T23:57:20-08:00
sewer_category
GRAVITY