Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 30, 2015, 09:02 AM
  • 22 0292_22 0291_20151230_012525.mp4

Date
12/30/2015
W/O
547382
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00793
PipeID
P16578
Time
1:02 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3020
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
32
Purpose
Routine Assessment
Project
WO_547382_TV22014_JAN2016
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
22 0291
Downstream MH
22 0292
Dir. of Survey
Upstream
Length Surveyed
427.1 ft.
Total Length
427.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2411
O&M Rating
9
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole 22 0291 to 22 0292
MH: 22 0291MH: 22 0292upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 02920 ft. MGO - General Observation - LATERAL AT MH 9 O'CLOCK ACTIVE0 ft. VC - Vermin Cockroach1.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1.9 ft. MGO - General Observation - MAGNESIUM H.O. FINISH1.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish6.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"31 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS INSIDE169.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"172.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"181.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"305.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"310.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"317.9 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS INSIDE322.6 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ROOTS INSIDE392.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"400.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"424.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start424.4 ft. MGO - General Observation - MAGNESIUM H.O. START424.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start427.1 ft. MWM - Water Mark, 10 %of cross sectional area427.1 ft. AMH - Downstream Manhole, Survey Begins - 22 0291427.1 ft. MWL - Water Level, 10 %of cross sectional area

Observations (23)

DistanceCodeObservation
396.1TFDROOTS INSIDE
0MWM
109.2TFDROOTS INSIDE
2.7DAGS
427.1AMH22 0292
427.1MGOLATERAL AT MH 9 O'CLOCK ACTIVE
116.5TFA
0AMH22 0291
34.5TFA
121.2TFA
245.9TFA
104.5TFDROOTS INSIDE
427.1VC
257.8TFA
425.2SAP
420.8TFA
26.5TFA
2.7MGOMAGNESIUM H.O. START
425.2MGOMAGNESIUM H.O. FINISH
2.7SAP
254.2TFA
425.2DAGS
0MWL

Properties (5)

additional_info
SC224612
custom_field_two
3
customer
LACSD
datetime
2015-12-30T01:02:24-08:00
sewer_category
GRAVITY